Nominal input voltage range | 100 V AC … 240 V AC |
AC input voltage range | 85 V AC … 264 V AC |
DC input voltage range | 90 V DC … 350 V DC |
AC frequency range | 45 Hz … 65 Hz |
DC frequency range | 0Hz |
Current consumption | Approx. 0.6 A (120 V AC) |
Approx. 0.4 A (230 V AC) | |
Approx. 0.8 A (90 V DC) | |
Approx. 0.3 A (350 V DC) | |
Inrush current limitation | < 35 A (typical) |
Power failure bypass | > 30 ms (120 V AC) |
> 150 ms (230 V AC) | |
Typical response time | < 1 s |
Input fuse, integrated | 2.5A (slow-blow, internal) |
Permissible backup fuse | 6 A / 10 A / 16 A ( characteristic B |
Nominal output voltage | ± 15 V DC ±1% |
Output current | 2x 1 A (-25 °C … 60 °C) |
2x 1.5 A (with POWER BOOST, -25°C … 40°C permanent) | |
Derating | +60°C to +70°C: 5% per Kelvin |
Current limitation | Approx 4.4 A (in the event of a short circuit) |
Control deviation | < 2 % (changein load, static 10% … 90%) |
< 3 % (change in load, dynamic 10% … 90%) | |
< 0.1 % (change in input voltage ±10%) | |
Efficiency | > 80 % (At 230 V AC and nominal values) |
Ascent time | < 100 ms (typ.) |
Residual ripple | < 30 mV(20 MHz) |
Peak switching voltages | < 20 mV(MHz) |
Connection in parallel | Yes, for assembling redundant systems and increasing efficiency |
Connection in series | Yes |
Resistance to reverse feed | 17 V DC |
Insulation voltage input/output | 3 kV (routine test) |
Mounting position | horizontal DIN rail NS 35, EN 60715 |
Degree of protection | IP20 |
Protection class | II (in an enclosed control cabinet) |
Type of housing | Polyamide PA, color: green |
Dimensions W / H / D (state of delivery) | 45 mm / 99 mm / 107 mm |
Weight | 0.25 kg |
Ambient temperature (operation) | 25°C … 70 °C (> 60 °C derating) |
Ambient temperature (storage/transport) | -40 °C … 85 °C |
Max. permissible relative humidity (oper<tion) | 95 % (at 25 °C, no condensation) |
Vibration (operation) | < 15 Hz, amplitude ±2.5 mm in acc. with IEC 60068-2-6 |
15 Hz … 150 Hz, 2.3g, 90 min. | |
Shock | 30g in all directions in acc. with IEC 60068-2-27 |
Pollution degree in acc. with EN 50178 | 2 |
Climatic class | 3K3 (in acc. with EN 60721) |
Type of connection | Pluggable screw connection |
Stripping length | 7mm |
68299497 ABB POWER SUPPLY MINI-PS100-240AC/2X15 (REPAIR SERVICE)
POWER SUPPLY
Weight | 0,25 kg |
---|---|
OPTIONS: |
Related products
ACS800 Spare Parts
1.580,66€
ACS800 Spare Parts
1.596,12€
ACS800 Repair Service
ACS800 Spare Parts
1.194,50€
Wind Sector Spare Parts
3.200,00€
ACS800 Repair Service
Wind Sector Repair Service
SACE E3(FG008)- ABB LOW VOLTAGE AIR CIRCUIT-BREAKERS (REPAIR SERVICE)
ACS800 Spare Parts
49,74€